Original EA Amendment

Description

Criteria

Units

Basis Value

Source

Wet season water storage allowance

1:100 AEP 3 month wet season rainfall depth 120 hr Probable Maximum Precipitation

mm

1,260

[3]

Design Flood Event

mm

2,620

[4], Refer Appendix C

Extreme storm storage

1:1,000 AEP 72 hr storm

mm

1,020

[5]

Minimum decant pond depth

-

m

No allowance at this stage

-

Project No PS213278 Upper Mundic Gully TSF Concept Design to RL 390 m Mount Morgan Project Heritage Minerals

WSP October 2025 Page 6