Original EA Amendment

LEGEND

EXISTING GROUND SURFACE AT 2 m CONTOUR INTERVALS

210

STAGE 1 EMBANKMENT DESIGN AT 2 m CONTOUR INTERVALS

210

STAGE 2 EMBANKMENT DESIGN AT 2 m CONTOUR INTERVALS EXISTING STORMWATER DIVERSION TUNNEL

MASS CONCRETE PLUG

STAGE 2 EMBANKMENT

MINE SPOIL (SIZING TBC)

STAGE 1 EMBANKMENT

ORIGINAL GROUND PRE MINING

EXISTING GROUND

SECURITY GATE FOR RESTRICTED ACCESS

MASS CONCRETE PLUG, APPROX. 6 m LONG

I.P. CH 284.51 RL 319

APPROX. 20 m

I.P. CH -13.21 RL 322

DATUM 310.00

TUNNEL INVERT

EXISTING GROUND

CHAINAGE

TUNNEL - LONG SECTION SCALE 1:1,000 m

STAGE 1 EMBANKMENT EXTENT

E 231196.0 m N 7383997.1 m RL 318.6 m TUNNEL OUTLET (NE)

EXISTING STORMWATER DIVERSION TUNNEL TO BE DECOMMISIONED

MINE SPOIL ZONE

E 230930.4 m N 7383862.6 m RL 321.8 m TUNNEL INLET (SW)

MASS CONCRETE PLUG

TUNNEL - PLAN VIEW SCALE 1:1,000 m

NOT FOR CONSTRUCTION PRELIMINARY

0

25

50

1:1,000

METRES

CLIENT

PROJECT

HERITAGE MINERALS

MOUNT MORGAN GOLD PROJECT UPPER MUNDIC GULLY - TSF CONCEPT DESIGN

TITLE

CONSULTANT

BRISBANE OFFICE 900 ANN STREET FORTITUDE VALLEY, QLD 4006 AUSTRALIA [+61] (7) 3854 6200

EXISTING STORMWATER DIVERSION TUNNEL - PLAN AND LONG SECTION

B 2025-07-04 PRELIMINARY - NOT FOR CONSTRUCTION

DT/DW

EN/TD

MJG

MJG

A 2024-08-26 DRAFT - FOR INFORMATION ONLY

DT/DW

EN/TD

MJG

MJG

DOCUMENT No. 019

6 6 of

FIGURE 006

PS2132478 PROJECT NO.

REV.

B

DESCRIPTION YYYY-MM-DD

PREPARED REVIEWED APPROVED DESIGNED

REV.

Powered by