Mount Morgan Mine Upper Mundic Gully TSF EA Amendment

Units

OCP WATER (before tailings contact)

OCP WATER (after tailings contact)

Var

Properties pH

-

4.1

4.2

TDS

mg/L mg/L

9,857

9,887

Hardness (as CaCO3)

12,564

13,078

+514

Anions

Chloride Sulphate

mg/L mg/L

270

290

8,400

7,600

-800

Cations (dissolved) Sodium as Na Calcium as Ca Aluminium as Al

mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L

730 490

800 460 510

1,400

-890

Copper as Cu

79

18 59 17

-61 +59 -59

Iron as Fe Lead as Pb

1

76

Magnesium as Mg Manganese as Mn

2,800

2,900

200

210

Zinc as Zn

60

53

4) Conclusions This test confirmed an overall improvement in the OCP water quality after adding final tailings residue from the ReCYN plant. There was a significant reduction in the aluminium, copper, lead and sulphate concentrations, with iron being the only metal concentration to increase. There were negligible changes in all other anion and cation concentrations.

Peter Papa (GGT Technical Director)